loader

World Tenders & Procurement Opportunities

e -Tender/STR/P2/HD/2021/33/REQN 1. Magnetic contactor, Coil voltage- 230 VAC, Number of main Contacts No-3 No, Number of Auxiliary contacts -1 No, Rated operational voltage-690VAC, Conventional free-air thermal current (Ith) 50A, Connecting thermills main poles Flat type C/W screws and bolts. (For LHB power car Radiator fan motor) 2. Thermal Magnetic Motor protection circuit Breaker, Rated operational voltage-690VAC, Rated operational current-10A, Setting range-6-10A, Number of Poles-3, Contact position Indication-ON/Off For LHB Power car Ventilation fan motor. 3. Thermal Magnetic Motor protection circuit Breaker, Rated operational voltage-690VAC, Rated operational current-63A, Setting range-45-63A, Number of Poles-3, Contact position Indication-ON/Off , Auxiliary contact - INO, For LHB Power car Radiator fan motor 4. Disconnecting and Earthing Device, 750 VAC (1000V insulation), 63 Amps, 8-pole, 2-way, contact position-ON/OF, Auxiliary contact -2NO+2NC with heavy handle and stainless steel box enclosure of dimension. part No-S63-73342-B32-LOGB, For LHB Non AC passengers Coach. 5. Magnetic contactor, Number of Poles-3, coil voltage-350-500VAC, Rated operational voltage-1000VAC, Rated operational current-1050A, Rated frequency (f)-50/60HZ, Short circuit protective devices-gG type fuse 1000A, Terminal type, Model No-AF750-30, For LHB Power car. 6. Mini contactor Relay, Coil voltage-24VDC, Minimum Switching capacity-17V, 5mA, Number of Auxiliary contact-2NO+2NC, Rated operational current-6A, Mounting type-DIN Rail, Mounting position-Any, Model No-TKC6-22Z, for LHB powercar.

World Biggest Tenders Source

This tender with title e -Tender/STR/P2/HD/2021/33/REQN 1. Magnetic contactor, Coil voltage- 230 VAC, Number of main Contacts No-3 No, Number of Auxiliary contacts -1 No, Rated operational voltage-690VAC, Conventional free-air thermal current (Ith) 50A, Connecting thermills main poles Flat type C/W screws and bolts. (For LHB power car Radiator fan motor) 2. Thermal Magnetic Motor protection circuit Breaker, Rated operational voltage-690VAC, Rated operational current-10A, Setting range-6-10A, Number of Poles-3, Contact position Indication-ON/Off For LHB Power car Ventilation fan motor. 3. Thermal Magnetic Motor protection circuit Breaker, Rated operational voltage-690VAC, Rated operational current-63A, Setting range-45-63A, Number of Poles-3, Contact position Indication-ON/Off , Auxiliary contact - INO, For LHB Power car Radiator fan motor 4. Disconnecting and Earthing Device, 750 VAC (1000V insulation), 63 Amps, 8-pole, 2-way, contact position-ON/OF, Auxiliary contact -2NO+2NC with heavy handle and stainless steel box enclosure of dimension. part No-S63-73342-B32-LOGB, For LHB Non AC passengers Coach. 5. Magnetic contactor, Number of Poles-3, coil voltage-350-500VAC, Rated operational voltage-1000VAC, Rated operational current-1050A, Rated frequency (f)-50/60HZ, Short circuit protective devices-gG type fuse 1000A, Terminal type, Model No-AF750-30, For LHB Power car. 6. Mini contactor Relay, Coil voltage-24VDC, Minimum Switching capacity-17V, 5mA, Number of Auxiliary contact-2NO+2NC, Rated operational current-6A, Mounting type-DIN Rail, Mounting position-Any, Model No-TKC6-22Z, for LHB powercar. has been published on Bidding Source portal dated 22 Oct 2021 for the country of Bangladesh. It has been categorized on Insulators and insulating fittings & Electricity poles & Fans & Ventilation equipment & Miniature circuit breakers & Pylons, poles and pickets & Bolts & Overhead circuit breakers & Insulation work & Thermal insulating material & Poles & Circuit breakers & Coach bolts and screws & Radiators & Central-heating radiators & Cooling and ventilation equipment & Bolts and screws & Poles for carrying overhead lines & Magnetic circuit breakers & Fuses. For similar tenders you can see tenders mentioned below of this page.

General Information

e -Tender/STR/P2/HD/2021/33/REQN 1. Magnetic contactor, Coil voltage- 230 VAC, Number of main Contacts No-3 No, Number of Auxiliary contacts -1 No, Rated operational voltage-690VAC, Conventional free-air thermal current (Ith) 50A, Connecting thermills main poles Flat type C/W screws and bolts. (For LHB power car Radiator fan motor) 2. Thermal Magnetic Motor protection circuit Breaker, Rated operational voltage-690VAC, Rated operational current-10A, Setting range-6-10A, Number of Poles-3, Contact position Indication-ON/Off For LHB Power car Ventilation fan motor. 3. Thermal Magnetic Motor protection circuit Breaker, Rated operational voltage-690VAC, Rated operational current-63A, Setting range-45-63A, Number of Poles-3, Contact position Indication-ON/Off , Auxiliary contact - INO, For LHB Power car Radiator fan motor 4. Disconnecting and Earthing Device, 750 VAC (1000V insulation), 63 Amps, 8-pole, 2-way, contact position-ON/OF, Auxiliary contact -2NO+2NC with heavy handle and stainless steel box enclosure of dimension. part No-S63-73342-B32-LOGB, For LHB Non AC passengers Coach. 5. Magnetic contactor, Number of Poles-3, coil voltage-350-500VAC, Rated operational voltage-1000VAC, Rated operational current-1050A, Rated frequency (f)-50/60HZ, Short circuit protective devices-gG type fuse 1000A, Terminal type, Model No-AF750-30, For LHB Power car. 6. Mini contactor Relay, Coil voltage-24VDC, Minimum Switching capacity-17V, 5mA, Number of Auxiliary contact-2NO+2NC, Rated operational current-6A, Mounting type-DIN Rail, Mounting position-Any, Model No-TKC6-22Z, for LHB powercar.
Invitation to Tender
e -Tender/STR/P2/HD/2021/33/REQN
Bangladesh
Rajshahi
22 Oct 2021
7 Nov 2021
English
Insulators and insulating fittings , Electricity poles , Fans , Ventilation equipment , Miniature circuit breakers , Pylons, poles and pickets , Bolts , Overhead circuit breakers , Insulation work , Thermal insulating material , Poles , Circuit breakers , Coach bolts and screws , Radiators , Central-heating radiators , Cooling and ventilation equipment , Bolts and screws , Poles for carrying overhead lines , Magnetic circuit breakers , Fuses

For viewing full details of tenders, you should Log in to your account. If not registered yet, Please Register Now

Or Request a call back now and one of our representatives will contact you. Contact us

No. 12, 1 st floor, Block B2, EGS Business Park, World Trade Center, Bakirkoy - Istanbul - Turkey
info@biddingsource.com
24 X 7 online support
TOP
For viewing latest tenders published for your business in all over the World: Sign in Join free
For accessing full details of Tenders, Kindly choose the Plan that works for you: View Subscription Plans