loader

World Tenders & Procurement Opportunities

e -Tender/STR/P2/HD/2021/33/REQN 1. Magnetic contactor, Coil voltage- 230 VAC, Number of main Contacts No-3 No, Number of Auxiliary contacts -1 No, Rated operational voltage-690VAC, Conventional free-air thermal current (Ith) 50A, Connecting thermills main poles Flat type C/W screws and bolts. (For LHB power car Radiator fan motor) 2. Thermal Magnetic Motor protection circuit Breaker, Rated operational voltage-690VAC, Rated operational current-10A, Setting range-6-10A, Number of Poles-3, Contact position Indication-ON/Off For LHB Power car Ventilation fan motor. 3. Thermal Magnetic Motor protection circuit Breaker, Rated operational voltage-690VAC, Rated operational current-63A, Setting range-45-63A, Number of Poles-3, Contact position Indication-ON/Off , Auxiliary contact - INO, For LHB Power car Radiator fan motor 4. Disconnecting and Earthing Device, 750 VAC (1000V insulation), 63 Amps, 8-pole, 2-way, contact position-ON/OF, Auxiliary contact -2NO+2NC with heavy handle and stainless steel box enclosure of dimension. part No-S63-73342-B32-LOGB, For LHB Non AC passengers Coach. 5. Magnetic contactor, Number of Poles-3, coil voltage-350-500VAC, Rated operational voltage-1000VAC, Rated operational current-1050A, Rated frequency (f)-50/60HZ, Short circuit protective devices-gG type fuse 1000A, Terminal type, Model No-AF750-30, For LHB Power car. 6. Mini contactor Relay, Coil voltage-24VDC, Minimum Switching capacity-17V, 5mA, Number of Auxiliary contact-2NO+2NC, Rated operational current-6A, Mounting type-DIN Rail, Mounting position-Any, Model No-TKC6-22Z, for LHB powercar.

World Biggest Tenders Source

This tender with title e -Tender/STR/P2/HD/2021/33/REQN 1. Magnetic contactor, Coil voltage- 230 VAC, Number of main Contacts No-3 No, Number of Auxiliary contacts -1 No, Rated operational voltage-690VAC, Conventional free-air thermal current (Ith) 50A, Connecting thermills main poles Flat type C/W screws and bolts. (For LHB power car Radiator fan motor) 2. Thermal Magnetic Motor protection circuit Breaker, Rated operational voltage-690VAC, Rated operational current-10A, Setting range-6-10A, Number of Poles-3, Contact position Indication-ON/Off For LHB Power car Ventilation fan motor. 3. Thermal Magnetic Motor protection circuit Breaker, Rated operational voltage-690VAC, Rated operational current-63A, Setting range-45-63A, Number of Poles-3, Contact position Indication-ON/Off , Auxiliary contact - INO, For LHB Power car Radiator fan motor 4. Disconnecting and Earthing Device, 750 VAC (1000V insulation), 63 Amps, 8-pole, 2-way, contact position-ON/OF, Auxiliary contact -2NO+2NC with heavy handle and stainless steel box enclosure of dimension. part No-S63-73342-B32-LOGB, For LHB Non AC passengers Coach. 5. Magnetic contactor, Number of Poles-3, coil voltage-350-500VAC, Rated operational voltage-1000VAC, Rated operational current-1050A, Rated frequency (f)-50/60HZ, Short circuit protective devices-gG type fuse 1000A, Terminal type, Model No-AF750-30, For LHB Power car. 6. Mini contactor Relay, Coil voltage-24VDC, Minimum Switching capacity-17V, 5mA, Number of Auxiliary contact-2NO+2NC, Rated operational current-6A, Mounting type-DIN Rail, Mounting position-Any, Model No-TKC6-22Z, for LHB powercar. has been published on Bidding Source portal dated 22 Oct 2021 for the country of Bangladesh. It has been categorized on Insulators and insulating fittings & Electricity poles & Fans & Ventilation equipment & Miniature circuit breakers & Pylons, poles and pickets & Bolts & Overhead circuit breakers & Insulation work & Thermal insulating material & Poles & Circuit breakers & Coach bolts and screws & Radiators & Central-heating radiators & Cooling and ventilation equipment & Bolts and screws & Poles for carrying overhead lines & Magnetic circuit breakers & Fuses. For similar tenders you can see tenders mentioned below of this page.

General Information

e -Tender/STR/P2/HD/2021/33/REQN 1. Magnetic contactor, Coil voltage- 230 VAC, Number of main Contacts No-3 No, Number of Auxiliary contacts -1 No, Rated operational voltage-690VAC, Conventional free-air thermal current (Ith) 50A, Connecting thermills main poles Flat type C/W screws and bolts. (For LHB power car Radiator fan motor) 2. Thermal Magnetic Motor protection circuit Breaker, Rated operational voltage-690VAC, Rated operational current-10A, Setting range-6-10A, Number of Poles-3, Contact position Indication-ON/Off For LHB Power car Ventilation fan motor. 3. Thermal Magnetic Motor protection circuit Breaker, Rated operational voltage-690VAC, Rated operational current-63A, Setting range-45-63A, Number of Poles-3, Contact position Indication-ON/Off , Auxiliary contact - INO, For LHB Power car Radiator fan motor 4. Disconnecting and Earthing Device, 750 VAC (1000V insulation), 63 Amps, 8-pole, 2-way, contact position-ON/OF, Auxiliary contact -2NO+2NC with heavy handle and stainless steel box enclosure of dimension. part No-S63-73342-B32-LOGB, For LHB Non AC passengers Coach. 5. Magnetic contactor, Number of Poles-3, coil voltage-350-500VAC, Rated operational voltage-1000VAC, Rated operational current-1050A, Rated frequency (f)-50/60HZ, Short circuit protective devices-gG type fuse 1000A, Terminal type, Model No-AF750-30, For LHB Power car. 6. Mini contactor Relay, Coil voltage-24VDC, Minimum Switching capacity-17V, 5mA, Number of Auxiliary contact-2NO+2NC, Rated operational current-6A, Mounting type-DIN Rail, Mounting position-Any, Model No-TKC6-22Z, for LHB powercar.
Invitation to Tender
e -Tender/STR/P2/HD/2021/33/REQN
Bangladesh
Rajshahi
22 Oct 2021
7 Nov 2021
English
Insulators and insulating fittings , Electricity poles , Fans , Ventilation equipment , Miniature circuit breakers , Pylons, poles and pickets , Bolts , Overhead circuit breakers , Insulation work , Thermal insulating material , Poles , Circuit breakers , Coach bolts and screws , Radiators , Central-heating radiators , Cooling and ventilation equipment , Bolts and screws , Poles for carrying overhead lines , Magnetic circuit breakers , Fuses

For viewing full details of tenders, you should Log in to your account. If not registered yet, Please Register Now

Or Request a call back now and one of our representatives will contact you. Contact us

Similar Tenders

Procurement of PC Pole 7.5 meter. - 7656968 Bangladesh (1) Supply and Installation of total 15 ton spilt type air cooler at Loan Classification Division, Head Office, Wage Earners Corporate branch building (5th floor), Head Office, Dhaka and (2) Replacement of 2.5 ton capacity 8 nos. … - 776531 Bangladesh Supply, Installation, Testing and Commissioning of Air cooler for C&P Room-1 at BIPTC, Bheramara under HVDC Circle, Power Grid. - 782262 Bangladesh Purchase of Fuse Cutout & Barrel storing at CWH (Dhk/Kln/Ctg) - 6760074 Bangladesh Supply, installation, testing & Commissioning of 01 No 24000 BTU/HR capacity Split type air Cooler for the Chief Medical Officer room and 01 No18000 BTU/HR Capacity Split type air Cooler for Doctor,s Room-02 of the Dental Departme… - 9671943 Bangladesh Supply and Installation of 07 (Seven) Air Coolers for Agrani Bank PLC., Wasa Corporate Branch, Dhaka & Sylhet West Zone Office. - 9671723 Bangladesh Procurement of Repairing works/servicing for HVAC system of Haripur 412 MW CCPP by suppling spare parts. - 9670602 Bangladesh Procurement of Vacuum Circuit Breaker (VCB), TYPE: 3AH5104-1 - 9670617 Bangladesh Replacement of duct insulation system and Leak repairing in tube of Carrier Brand Chiller in/c other related works for Central Air Conditioning system of Terminal Building-2 at HSIA. - 8458447 Bangladesh Supply of Different size Magnetic Contractor and Circuit breaker for IPTB and Domestic Terminal Building at HSIA - 8458802 Bangladesh
No. 12, 1 st floor, Block B2, EGS Business Park, World Trade Center, Bakirkoy - Istanbul - Turkey
info@biddingsource.com
24 X 7 online support
TOP
For viewing latest tenders published for your business in all over the World: Sign in Join free
For accessing full details of Tenders, Kindly choose the Plan that works for you: View Subscription Plans